Check out qualified professional on the house to the customer. Replacement pre-filters, water quality testing. Flushing the membrane. Optional - replacement of post-filter, mineralizing agent, bioactivator membranes (if necessary). Full diagnostics reverse osmosis filter - the sealing compounds, the condition of the tank, valves, a reverse osmosis membrane. On request, we include a semi-automatic SMS service to inform about the necessity of the calendar service.
Order a replacement cartridge reverse osmosis can place an order on our website or contact us in any convenient way for you.
Technical information | |
Execution | Time of work negotiated with the customer |
Kind | The types and value of the work stipulated in each case |
Country | Ukraine |
Instructions replaceable cartridge pre-filter using a set of one polypropylene cartridge and two coal.
1. Shut off the water supply to the system and turn the ball valve of the tank to the "Closed".
2. Remove the key of the first two flasks (along the water) prefilters. Be careful - the flask filled with water.
3. Remove the used cartridges.
4. Wash the flask with detergent and rinse with water.
5. Insert the new ink cartridges in the first and second bulb in the course of the movement of water. Screw the bulb hands. You can hang on the bulb key without applying excessive force.
6. Remove the tube connecting the third in the direction of the water flask with a membrane.
7. Open the water tap and pass through the first two flasks with new cartridges 5-7 liters of water.
Attention!!!
This water will pour through the branches of the membrane tube, so you need a container for its collection.
8. Remove the key of the third pre-filter flask. Be careful: the bulb is filled with water.
9. Remove the spent cartridge.
10. Wash the flask with detergent and rinse with water.
11. Insert the cartridge in the direction of the third movement of the water flask, screw the flask hands again miss 4 liters of water to wash the coal dust.
12. Connect the receiver to the previously separated avtoregulyator.
13. Reverse Osmosis Filter is ready for operation.
The normal rate of water purification - at least one liter for 10 minutes. If the rate of water treatment is less than 0.5 liters in 10 minutes, you need to replace the membrane.
If the water flow has a normal speed, open the ball valve of the tank.
Note.
If you use one set of cartridges of coal and two polypropylene (in the first and third stages), you can immediately install all three modules, missing washing steps (coal dust from the second stage will be delayed third stage - polypropylene cartridge).
Instructions replaceable membrane
1. Turn off the water supply to the system.
2. Release the entire supply of drinking water through the valve and turn off the storage tank.
3. Open the valve of treated water pressure-relief system.
4. Disconnect the housing cover of the membrane.
5. Remove the cover membrane.
6. Remove the membrane used (remember its location in the body).
7. Apply silicone grease to the rubber seals of the new membranes and membrane sealing the housing cover.
8. Install a new diaphragm into the housing, observing the direction and position of the tube.
9. Screw the cover of the membrane.
10. Connect the receiver to the housing cover of the membrane.
11. Turn off the purified water.
12. Open the valve of the storage tank.
13. Open the water tap on.
14. After filling the tank (you will hear that the water flow is stopped), drain all water from the tank into the sink, the spigot of purified water.
15. Once the water pressure will dry out, close the valve of treated water to refill the tank. Depending on the pressure in your water tank filling system may take from 1.5 to 3 hours. After re-filling the tank can drink the treated water.
Instructions for replacement of coal postfilter
1. Turn off the water supply to the system.
2. Turn off the storage tank.
3. Open the valve of treated water pressure-relief system.
4. Disconnect the tubing that connects to the system postkarbon.
5. Remove the spent postkarbon with plastic holders (clips).
6. Install the new postkarbon the removed guided arrows that indicate the direction of flow.
7. Connect the tube that connects to the system postkarbon. If you use the cartridge without the built-in fitting, first screw it necessary adapters.
8. Open the water tap on. Open the ball valve of the storage tank.
9. flush the drain for 10-15 minutes.
10. Turn off the purified water.
Instructions for replacing the mineralizer
1. Turn off the water supply to the system.
2. Turn off the storage tank.
3. Open the valve of treated water pressure-relief system.
4. Disconnect the tubing that connects to the mineralizing system.
5. Remove the mineralizer used with plastic holders (clips).
6. Install a new mineralizing the removed guided arrows that indicate the direction of flow.
7. Connect the tube that connects to the mineralizing system. If you use the cartridge without the built-in fitting, first screw it necessary adapters.
8. Open the water tap on. Open the ball valve of the storage tank.
9. flush the drain for 10-15 minutes.
10. Turn off the purified water.
Reverse osmosis filter in Kharkov. Reverse osmosis system with the installation. Components, membranes, cartridges. Maintenance, repair, service. Osmos Kharkiv. Osmos Ukraine.
Our sites - Osmos Kharkiv, Osmosovsky, ro-5.com, Service Osmos. Information resource of company group Osmosovsky © 2006 - 2023
Плюсы: Как всегда заказ выполнен быстро.Все остались довольны.
Плюсы: предложили комплект картриджей на выбор, как всегда внимательны
Минусы: нет
Плюсы: Качеством системы и чистотой воды очень доволен. Работа Вячеслава не вызывает никаких нареканий. Все делает быстро и добросовестно. Цены на товар, комплектующие, расходные материалы и за обслуживание вполне адекватны.
Минусы: Чисто субъективно, вода после фильтра кажется горьковатой. Хотя приборы показывают отличный уровень очистки. Доустановил картридж-минерализатор. Вода стала мягче, но не намного.