In reverse osmosis systems range of accessories is a limited resource. The filter needs periodic diagnosis and replacement of defective items. One skilled in place verify operation and, if necessary, will shape the reverse osmosis filter. We also we obtain to diagnose system (it's easier than to meet and see off a series of amateurs and beginners "experts" without result).
Order repair reverse osmosis can place an order on our website or contact us in any convenient way for you.
Technical information | |
Execution | Time of work negotiated with the customer |
Kind | The types and value of the work stipulated in each case |
Country | Ukraine |
Some problems of reverse osmosis filter and possible solutions
malfunction
|
Reason
|
How to fix
|
the flow of water from the fittings
|
not tightly connected tube
|
disconnect and reconnect the tube
|
flowing out of the drain clip
|
drain hose clamp properly installed
|
Install the drain hose clamp
|
flowing from the bulb
|
incorrectly installed grommet
|
Check the installation of the sealing ring (the trough of the flask)
|
the bulb screwed in securely
|
tighten the flask
|
|
tap water is flowing very poorly
|
a low pressure inlet system
|
Check the inlet pressure. if the pressure is lower than 3 atm. - Set the booster pump
|
contaminated prefilter cartridges
|
Replace the pre-filter cartridges
|
|
polluted membrane
|
Replace membrane
|
|
pinched connecting pipe
|
Check the entire length of the tube
|
|
low pressure in the storage tank
|
the pressure in the storage tank without water should be 0.4-0.6 atmospheres. if necessary, pump up the pressure pump. surgery performed by a specialist service center (SC)
|
|
increased noise level
|
air avtoregulyator
|
air will be expelled from avtoregulyator naturally after a while
|
inlet pressure system above provisions
|
install a pressure regulator. contact SC
|
|
knock avtoregulyator
|
pressure fluctuations in the network
|
install a check valve on the inlet water supply to the apartment.Check the pressure in the diaphragm tank is dry. the pressure in the storage tank without water should be 0.4-0.6 atmospheres. if necessary, pump up the pressure pump. surgery performed by a specialist SC
|
Water constantly flows into the drain.
|
a low pressure inlet system
|
Check the inlet pressure. if the pressure is lower than 3 atm. - Set the pump step-up
|
contaminated prefilter cartridges
|
Replace the pre-filter cartridges
|
|
polluted membrane
|
Replace membrane
|
|
faulty avtoregulyator
|
test the avtoregulyator (with ball valve closed storage tank avtoregulyator a few minutes should stop the water supply to the system). contact SC
|
|
faulty check valve in the diaphragm casing
|
faulty check valve in the storage tank is full, the water discharge in the drainage stops. contact SC
|
|
low pressure in the collecting tank
|
Check the pressure in the storage tank dry. the pressure in the storage tank without water should be 0.4-0.6 atmospheres. if necessary, pump up the pressure pump. surgery performed by a specialist SC
|
|
missing or incorrectly set flow limiter
|
check that the flow restrictor at the outlet of membranoderzhatelya (membrane housing). it must be inserted into the tube and black connected to the output of membranoderzhatelya. If the side of the tube, which is inserted into the flow restrictor is directed into the sewer - move the tube (cleared limiter). If the flow restrictor is not - perhaps it was washed into the sewer. install a new flow limiter (connect the end of the tube with the stopper out of the membranoderzhatelya).
|
|
Water does not flow out of the drain pipe at the water supply to the system
|
the storage tank is full
|
open the valve of treated water. if after draining purified water from the tank will flow into the drain - the system is operating normally
|
clogged flow restrictor
|
Clean or replace the flow restrictor
|
|
mismatch in the drain hole collars and sewer
|
install the drain hose clamp properly, recheck the system
|
|
Water has a white color, which disappears on standing
|
air in the system
|
air in the system - at the beginning of normal system operation. after some time passes this effect.Attention! air bubbles may appear in the treated water in the cold season, when large temperature difference water and space
|